Digital slit lamp camera system Oculus ImageCam 2, NEW!
Delivery Time: 1-2 weeks
Description
Digital slit lamp camera system Oculus ImageCam 2, NEW!
One of the smallest digital slit lamp camera systems
A slit lamp image or video sequence is taken by the high resolution, digital video camera in the beam path of the slit lamp. Exposure time, light magnification and white balance
can be easily adjusted with its user-friendly software.
Suitable exposure parameters for taking pictures in different segments of the eye such as anterior segment, fundus, sclera etc. can be stored conveniently under appropriate names.
Beam splitter
Compact size increases slit lamp length minimally
Prism can be moved in and out of the beam path of the slit lamp:
Out: no optical impairment
In: maximum light for taking pictures
Adjustable aperture for greater depth of field:
bright image taking situation small aperture, more depth of field for sclera
and overview in anterior segment
dark image taking situation large aperture, lower depth of field for fundus
and fluo images, but more light for the camera
Software
Patient data management program
Live image shown on monitor
Single image or video sequence
Single image mode for detailed images and four image mode for comparison
Loupe function
Comment field for notes
Image optimization possible (color, brightness, contrast, )
Storage of selected images on hard disk
Printout of selected images
Image release by mouse click or footswitch
Camera
Camera
digital camera 2 megapixel
Interface
USB-2
Dimensions (H x W x D)
1.34 x 1.26 x 1.35 inches (34 x 32 x 34,4 mm)
Weight
Beam splitter
2.61 ounces (74 g)
Splitter rate
70/30 (camera / view)
Splitter prism
can be swiveled in and out
Aperture
adjustable
Weight
Software
11.82 16.93 ounces (335 g - 480 g, as per model)
Network compatible
data base with
Minimum Requirements
image viewer
- image processing
- camera control
- print and export function
Picture format: JPG, JPG2000, BMP
Video format: MPEG
Laptop:
WIN 2000, Windows XP Prof. SP2
or Windows Vista Home Premium
CPU: AMD Turion 64 MT-32 / Pentium m Dothan 730
RAM: 1024 MB
HD: 40 GB
Display: XGA (1024 x 768), WXGA (1280 x 800)
Drive: CD/RW or DVD/RW
2 free USB 2.0-interfaces, one of them unshared
PC:
CPU: Intel P4 3,6 Ghz / AMD according to
RAM: 1024 MB
HD: 40 GB
Display: SXGA (1280 x 1024)
Drive: CD/RW or DVD/RW
2 free USB 2.0-interfaces, one of them unshared
The ImageCam 2 is adaptable to common slit lamps in the market.
Please find the Slit lamp adaptions at the PDF belonging to this offer.
One of the smallest digital slit lamp camera systems
A slit lamp image or video sequence is taken by the high resolution, digital video camera in the beam path of the slit lamp. Exposure time, light magnification and white balance
can be easily adjusted with its user-friendly software.
Suitable exposure parameters for taking pictures in different segments of the eye such as anterior segment, fundus, sclera etc. can be stored conveniently under appropriate names.
Beam splitter
Compact size increases slit lamp length minimally
Prism can be moved in and out of the beam path of the slit lamp:
Out: no optical impairment
In: maximum light for taking pictures
Adjustable aperture for greater depth of field:
bright image taking situation small aperture, more depth of field for sclera
and overview in anterior segment
dark image taking situation large aperture, lower depth of field for fundus
and fluo images, but more light for the camera
Software
Patient data management program
Live image shown on monitor
Single image or video sequence
Single image mode for detailed images and four image mode for comparison
Loupe function
Comment field for notes
Image optimization possible (color, brightness, contrast, )
Storage of selected images on hard disk
Printout of selected images
Image release by mouse click or footswitch
Camera
Camera
digital camera 2 megapixel
Interface
USB-2
Dimensions (H x W x D)
1.34 x 1.26 x 1.35 inches (34 x 32 x 34,4 mm)
Weight
Beam splitter
2.61 ounces (74 g)
Splitter rate
70/30 (camera / view)
Splitter prism
can be swiveled in and out
Aperture
adjustable
Weight
Software
11.82 16.93 ounces (335 g - 480 g, as per model)
Network compatible
data base with
Minimum Requirements
image viewer
- image processing
- camera control
- print and export function
Picture format: JPG, JPG2000, BMP
Video format: MPEG
Laptop:
WIN 2000, Windows XP Prof. SP2
or Windows Vista Home Premium
CPU: AMD Turion 64 MT-32 / Pentium m Dothan 730
RAM: 1024 MB
HD: 40 GB
Display: XGA (1024 x 768), WXGA (1280 x 800)
Drive: CD/RW or DVD/RW
2 free USB 2.0-interfaces, one of them unshared
PC:
CPU: Intel P4 3,6 Ghz / AMD according to
RAM: 1024 MB
HD: 40 GB
Display: SXGA (1280 x 1024)
Drive: CD/RW or DVD/RW
2 free USB 2.0-interfaces, one of them unshared
The ImageCam 2 is adaptable to common slit lamps in the market.
Please find the Slit lamp adaptions at the PDF belonging to this offer.
Additional Informations
Query on the Item?