Zeiss IOLMaster 700 incl. table & printer, NEW!

Description

Zeiss IOLMaster 700, incl. electr. table and printer, NEW

The new ZEISS IOLMaster 700
with SWEPT Source Biometry
ZEISS was the inventor of the first optical biometer and pioneered the introduction of OCT for ophthalmology.
We have now integrated SWEPT Source OCT technology into biometry to create the first SWEPT Source Biometry
device from ZEISS.
Defining next generation biometry from ZEISS.

Your key benefits
Get fewer refractive surprises OCT image based biometry for visually verifying measurements and for the detection of unusual eye geometries

Improve your refractive outcomes
Repeatability, clinical foundation, telecentric
keratometry, biometrical parameters

Optimize your workflow
On-board toric IOL power calculation,
easy delegation, measurement speed,
markerless implantation of toric IOLs

Make a future-proof investment
Platform ready for future enhancements,
hassle-free service package

Get fewer refractive surprises
Detect unusual eye geometries
The SWEPT Source Biometry performed by the
IOLMaster

700 from ZEISS provides a full-length
OCT image showing anatomical details of the eye
on a longitudinal cut through the entire eye. Thus,
for the first time in optical biometry, unusual eye
geometries, such as a tilt or decentration of the
crystalline lens, can be detected. If left undetected,
such critical details can lead to an unsatisfactory
post-operative visual experience.

Detect poor fixation
The unique Fixation Check of the IOLMaster 700
provides you with more confidence in biometry.
Can you see the foveal pit? If so, you can reduce
the risk of refractive surprises due to incorrect
measurements caused by undetected poor fixation.
If not, you can educate your patients to always
fixate on target.

Visually verify your measurement
All measurement calipers are shown on the full-length OCT image provided by the ZEISS IOLMaster 700.
Now, for the first time in biometry, you can visually verify what structure of the eye has been measured.
The complex interpretation of A-scans and guesswork as to which peak might be the right one to be
measured are no longer necessary. Thus, potential sources of errors are eliminated.

Outstanding repeatability
Repeatability is essential for good refractive
outcomes. Thanks to its unique SWEPT Source
Biometry with 2,000 scans per second, the
repeatability of the ZEISS IOLMaster 700 is
absolutely outstanding.

Get the broadest basis of clinical data
The biometry of ZEISS IOLMaster 700 is 100
% compatible with former versions of the IOLMaster. Therefore, you can
leverage the complete “User Group of Laser Interference Biometry” (ULIB) database. You will find optimized lens
constants for more than 270 IOL models based on the data from over 50,000 cataract surgeries specifically collected
for the IOLMaster. This will help you to improve your refractive outcom.

Unique telecentric keratometry
ZEISS is the only company that offers a biometer
with telecentric, and thus distance-independent,
keratometry. Its smart optical configuration allows
robust and repeatable measurements – especially
with restless patients – for superior keratometry
measurements.

Complete set of biometric parameters
for latest IOL power calculation formulas
The ZEISS IOLMaster 700 measures all biometric
parameters for the latest IOL power calculation
formulas.

Toric IOL power calculation made easy
In the new Haigis Suite, the ZEISS IOLMaster 700
provides the first on-board all-in-one solution for
toric IOL power calculation. It combines the well
established Haigis formula, the Haigis-L formula
for post-LVC cases, and the new Haigis-T for toric
IOL in one powerful tool. There is no need to key-in
data into the vendors’ online toric IOL power
calculation tools.

Easy to use and delegate
Taking biometry measurements made easy! The
multi-touch screen and the new graphical user
interface allow for gesture control of the device
like you are used to from your smartphone or
tablet computer.
Alignment assistance functions make the results
largely independent from the user and therefore
easy to delegate.

Fast
Thanks to its SWEPT Source Biometry, the measure-
ments take only seconds. This is a huge advantage –
especially with restless patients.

Implant toric IOLs markerless – ZEISS Cataract Suite
markerless
The ZEISS IOLMaster 700 is part of the
ZEISS Cataract Suite markerless.
It acquires a reference image in case of astigmatism during routine biometry. The image of the eye is taken along with the keratometry measurement, all with one device. Both, reference image and keratometry
data are transferred to CALLISTO eye, the computer-assisted cataract surgery system from ZEISS.
During surgery, the image is used for intra-operative matching with the live eye image. All data needed is injected into the eyepiece of the surgical microscopes of the OPMI LUMERA
Pre-operative corneal marking and additional measurements for toric IOL alignment
become obsolete.


Please find further technical detail concerning this device in the PDF for this offer.

Reviews

Query on the Item?

Do you have any questions on this item?

Email:

My Question: